  1. Drilled Pier Frost Heave | Eng-Tips

    Feb 11, 2025 · Hello, I am currently designing concrete drilled piers, and per the geotech report, the recommendations incur a 1600 psf design stress for potential frost heave. The recommendations …

  2. Frost Depth | Eng-Tips

    Oct 1, 2025 · Frost depth also tends to presume a bit of "heated building" in the tabulated numbers, so keep that in mind for say, a freezer building, unheated storage, etc.

  3. "Landscaping" Retaining Wall- Frost Depth? | Eng-Tips

    Apr 13, 2011 · Section 1809.5 of IBC 2009 deals with frost depth and leaves most of the requirements up to the local jurisdiction. You may want to look in this section to see if you can work your way out of …

  4. Frost Protection for Interior Footings | Eng-Tips

    Nov 18, 2024 · If the building is heated there is no need to frost protect interior footings. On the other hand, if the structure is an unheated warehouse, then they should be protected just as exterior …

  5. Frost depth for turndown slab | Eng-Tips

    Jul 30, 2010 · I have virtually an unheated metal shack. It will sit on a slab on grade with a turndown. Is is necessary for the turndown to bear below the frost depth? In my mind, only unheated bearing …

  6. Sources for Frost Depth Values | Eng-Tips

    Mar 1, 2022 · Hello all, this is my first post here so please bear with me. Where do you go to find accurate frost depth/line values? At my job, we often have to design footers/foundations rapidly so as …

  7. Can foundation weight allow avoidance of frost depth? | Eng-Tips

    Mar 3, 2011 · A contractor is suggesting the use of 1ft deep, very wide concrete slab to support heavy rotating equipment. The local jurisdiction has a required frost depth 42in. Can a very heavy …

  8. Frost protection of foundations | Eng-Tips

    Aug 10, 2015 · Frost depth in busy roads, normal winter 5-7 feet, residential roads 46 feet in the yards adjacent to both roads, 2-3 feet. And yes when I was there we installed and repaired sewer pipes all …

  9. Frost protection - void form thickness design | Eng-Tips

    May 24, 2009 · Hi all, this may be old to someone but i need your input on frost heave design for my foundation. I'm designing an unheated structural slab supported on piles. Design depth of frost …

  10. Frost Penetration and Movement | Eng-Tips

    Oct 21, 2009 · Frost penetration and frost depth effects are really two different animals. As OldestGuy indicated, even in very cold climates, they recognize that footings do not have to go full depth of frost …